Applies to:
Compression and backpack sprayers built by The Fountainhead Group, including Field King, Smith Performance, Grab & Go, and Indian models.
What causes this:
- A worn or damaged pump piston seal (the most common cause)
- A loose or cracked pump tube
- A faulty pressure check valve
- A damaged tank lid gasket
How to fix it:
- Relieve all tank pressure before you open anything.
- Remove the pump and inspect the piston O-ring for wear or drying.
- Apply food-grade silicone grease to the piston O-ring, then reassemble.
- Check the pump tube and tank lid gasket for cracks or a loose fit.
- If pressure still drops, install a pump repair kit for your model.
Pump repair kits and replacement seals for most FGI models are available at the FGI parts store. Find the part you need.
Still stuck? Call us at 1-800-311-9903 or send a message. Monday to Friday, 8AM to 5PM EST.