Applies to:
ULV17 Cold Fogger and similar ULV (Ultra Low Volume) fogger units from The Fountainhead Group.
What causes this:
The ULV17 fogger is designed for water-based and water-soluble disinfectants, sanitizers, insecticides, and deodorizers. Using the wrong chemical type can damage the pump and seals, void the warranty, and create a safety hazard.
How to fix it:
- Use only water-based or water-soluble products that the chemical maker labels as compatible with cold ULV foggers.
- Do NOT use oil-based products; they can damage the pump seals and motor and create a fire hazard near electrical components.
- Do NOT use flammable solvents, gasoline, alcohol-based products above the rating for cold foggers, or aerosol propellants.
- Always check the chemical's Safety Data Sheet to confirm fogger compatibility before use.
- Wear appropriate PPE (goggles, gloves, mask, protective clothing) as the chemical maker recommends.
- Clean the fogger with clean water after every use; residue from one chemical can react with the next.
- Unsure about a product? Check our chemical compatibility tool or call 1-800-311-9903 before using it. Incompatible chemicals void the warranty.
Still stuck? Call us at 1-800-311-9903 or send a message. Monday to Friday, 8AM to 5PM EST.