Material overflows through the pump barrel or the handle rises

This is a check-valve problem: debris under the valve, or a chipped, torn, or swollen valve. Clean the check valve and its sealing surface, and replace the valve if damaged.

Updated June 3, 2026

Applies to:

FGI manual pump sprayers (Universal 181383, Smith 190229/190230/190399, DEWALT DXSP190612, and others).

What causes this:

Liquid pushes up through the pump barrel, or the pump handle rises when unlocked. This is caused by dirt or debris under the pump check valve, or a check valve that is chipped, torn, or swollen.

  • Dirt or debris under the check valve
  • A chipped, torn, or swollen check valve

How to fix it:

  1. Empty the tank and relieve all pressure first.
  2. Clean the check valve and the valve sealing surface on the pump, removing any dirt or debris.
  3. Inspect the check valve; if it is chipped, torn, or swollen, replace it.
  4. Reassemble and test with clean water.

Replacement pump check valves are available at the FGI parts store. Find the part you need.